NorthStar Order Entry supports scales that use the "NCI Weigh-Tronics" protocol. It is known to work with the following models:
- Brecknell 6710U
- Mettler Toledo Ariva-S
Table of Contents
General Instructions
Adjust the level
Before installing or connecting cables, adjust the level on the scale.
- Lift the metal plate on the top of the scales to expose the built-in level for the scale.
- Brecknell 6710U - Level
- Mettler Toledo Ariva-S - Level
- Adjust the leg stands on each of the scales until the small bubble in the level is in the center of the circle.
Connect units and cables
- Each scale will have its own display unit and cables provided.
- Follow the manufacturer's manual to properly attach the:
- display unit
- power cable
- serial cable
3. These are the connection ports on the sides of the scales:
Brecknell 670U - Ports | Mettler Toledo Ariva-S - Ports |
4. After the cables and display are connected, connect the scales to the Lantronix device to provide it a COM #. You will enter this COM # in ECM.
You can follow the Lantronix document: Installing a Lantronix Serial-to-Ethernet Device
Troubleshooting: NorthStar Order Entry: Lantronix + Scale data inconsistency troubleshooting
Device-specific information
Brecknell 6710U
The Brecknell 6710U scale uses a straight-through serial cable. It does not work with a null modem cable.
Brecknell 6710U configuration
- User
- COM2
- BudRt (Baud Rate): "9600"
- Bt.Fmt (Bit Format): "7E1"
- OutMd (output mode): "Cmd" or "Prt.Cd"
- Lyout (Layout): SCP01
- COM2
Mettler Toledo Viva
The Mettler Toledo Viva scale uses a null modem cable. It does not work with a straight-through serial cable.
Mettler Toledo Viva Configuration (Viva PDF Document attached to this page)
Setup
This mode allows an operator to change certain soft switches directly from the keyboard. While turning on the
power, press and hold >0< key until “grP 1” is displayed. The scale is configurable for your specific needs
with a special interactive set up procedure. In order to access the various prompts, you must utilize the
following keys during the scale setup mode.
>0<
This key is used to confirm the choice and then go to the next step.
>T<
This key is used to step through the set up groups. Once a group is accepted, this key is
used to select the soft switch settings
Make sure to follow these settings for the scale within the GROUPS in the setup.
GRP1:
1.5: OFF
GRP2:
2.4: 2
- GRP3:
- 3.1: 3
- 3.2: 1
- 3.3: 0
- 3.4: 1
- 3.5: 8
- Save Settings by pressing >0<