Brecknell 67xx Serial Scale User Manual.pdf
- Page 52, "7.1 Communication Settings", gives instructions on the configuration below
Brecknell 6710U configuration
- For Windows: a double male USB cable is needed to connect the scale to the windows app.
- User
- Com 1 (USB)
- BudRt (Baud Rate): "9600"
- Bt.Fmt (Bit Format): "7o1"
- OutMd (output mode): "Prt.Cd"
- Lyout (Layout): SCP02
- Com 1 (USB)
- User
- For iOS: a serial cable and Lantronix box is needed to connect the scale to the iOS app.
- User
- COM2 (Serial Port)
- BudRt (Baud Rate): "9600"
- Bt.Fmt (Bit Format): "7E1"
- OutMd (output mode): "Cmd" or "Prt.Cd"
- Lyout (Layout): SCP01
- COM2 (Serial Port)
- User
- There is also a screw on the bottom of the Brecknell 6710U that needs to be removed if the scale is not showing accurate numbers. This is the shipping screw.
- Once removed a zero calibration will need to be done.
- Cal
- Cal-on
- Zero
- Cal-on
Mettler Toledo Viva
The Mettler Toledo Viva scale uses a null modem cable. It does not work with a straight-through serial cable.
...